Short answer
Hide the pump in a skimmer box or pump vault, screen the filter with planting or a timber box, and run cables in conduit under the edging. Keep everything reachable for maintenance. Protect every electrical connection with GFCI (US) or 30 mA RCD (UK) protection.
Hide the pump
A submersible pump can sit in a skimmer box or a pump vault. Both hide it from view, screen it from debris, and keep it easy to reach. Size the pump so it turns the whole pond volume over at least once an hour.
Unplug the pump before you handle it in the water.
Screen the external filter
External filters are usually easiest to hide, because they can sit outside the pond. Some options:
- Screen the filter with shrubs, a faux-rock cover or a timber box.
- Partly bury the filter, with the lid still accessible.
- Use a waterfall filter (biofalls), which hides inside the rockwork of the waterfall.
Filters need cleaning once a week to once a month, depending on fish numbers. Keep access to the filter and the lid clear, and do not bury it completely.
Run cables and tubing safely
Run cables under the edging in conduit, and never through the liner. Mark the route of any buried cable or tubing, so you can find it later.
Burial depths vary by country and by installation. For reference only:
- US (NEC 300.5): direct-burial UF cable 24 in (60 cm); PVC conduit 18 in (45 cm); a GFCI-protected 120 V circuit of 20 A or less, 12 in (30 cm). Check your local code, because it can be stricter.
- UK: armoured (SWA) cable is commonly buried at about 450 to 600 mm. In England and Wales, new circuits are usually notifiable under Part P, so use a registered electrician.
Flexible tubing, such as an air line, can sit shallowly beneath the surface. Mark its route.
Electrical safety at the pond
- Use GFCI (US) or 30 mA RCD (UK) protection on every pump, light and outlet near the water.
- Use an outdoor receptacle with an in-use (bubble) cover. Leave a drip loop in the cord, so water runs away from the plug.
- Keep receptacles about 6 feet (1.8 m) from the water. This is common guidance, and local code may differ.
- Use IP68 connectors for any joint that will be submerged, and an IP44 or higher junction box outdoors.
- Use a licensed or registered electrician for any new outdoor circuit.
Mowers and trimmers used near the pond also need RCD or GFCI protection. See mowing and lawn edges around a pond.
Solar and air pump options
Solar panels need full sun, which may be some distance from the pond. Plan the cable or pipe run before you place the panel.
An air pump should sit dry and above the water line. Alternatively, fit a check valve so water cannot siphon back into the pump.
Mistakes to avoid
- Burying a filter completely. You will lose access to it for cleaning.
- Cutting the plug off and splicing the cable. This can void warranties and breach code.
- Using indoor extension cords outdoors. They are not built for wet conditions.
For cables and tubing that run past toddlers or pets, check the safety advice in pond fencing and safety barriers for kids and pets. The edging also hides runs well; see pond edging.